Hackspace Access Control/Card Entry Sentry System (HACCESS) is a series of access control nodes spread around the hackspace, used for access to machines that require special training or an induction.  And also to turn the coffee pot off.
 
Hackspace Access Control/Card Entry Sentry System (HACCESS) is a series of access control nodes spread around the hackspace, used for access to machines that require special training or an induction.  And also to turn the coffee pot off.
 +
 +
==Usage==
 +
The plan is to eventually to replace the isolation switches on the benches and the kitchen worktop with HACCESS nodes, so that we can have a HACKSPACE OFF button by the door, and monitor what is on / off from the interweb.  The user will come up to a device they want to use and press the green button.  If the device needs RFID, it will ask for it to be scanned, if not it turns on.  Each press of the green button while authenticated adds 30 minutes to the timer, so you go to the bench, press green twice for an hour.  If its getting close to the end of the timer, the beeper starts beeping, and the user can press it again for another 30 minutes.
  
 
==Basic Design==
 
==Basic Design==

Revision as of 13:37, 21 May 2014

Haccess.png

Hackspace Access Control/Card Entry Sentry System (HACCESS) is a series of access control nodes spread around the hackspace, used for access to machines that require special training or an induction. And also to turn the coffee pot off.

Usage

The plan is to eventually to replace the isolation switches on the benches and the kitchen worktop with HACCESS nodes, so that we can have a HACKSPACE OFF button by the door, and monitor what is on / off from the interweb. The user will come up to a device they want to use and press the green button. If the device needs RFID, it will ask for it to be scanned, if not it turns on. Each press of the green button while authenticated adds 30 minutes to the timer, so you go to the bench, press green twice for an hour. If its getting close to the end of the timer, the beeper starts beeping, and the user can press it again for another 30 minutes.

Basic Design

  • RC522 RFID reader
  • 5110 LCD Unit
  • 1 or 2 buttons
  • Buzzer for alerting
  • Comms, any of:
    • ENC28J60 Ethernet
    • nRF24L01 Wireless Module
    • RS485
  • Output Devices, any of:
    • Opto Coupler
    • FET
    • Relay
    • SSR
  • Sized to fit in a regular single pattress, with a laser cut front

Parts & Modules Purchased